YASKAWA_U1000_706str_ang.pdf

(55734 KB) Pobierz
Low Harmonic Regenerative Drive for Industrial Applications
U1000 Industrial MATRIX Drive
Technical Manual
Type: CIMR-UU
Models: 200 V Class: 7.5 to 75 kW (10 to 100 HP ND)
400 V Class: 5.5 to 580 kW (7.5 to 775 HP ND)
Receiving
1
2
3
4
5
6
7
8
A
B
C
D
E
Mechanical Installation
Electrical Installation
Start-Up Programming &
Operation
Parameter Details
Troubleshooting
Periodic Inspection &
Maintenance
Peripheral Devices &
Options
Specifications
Parameter List
MEMOBUS/Modbus
Communications
Standards Compliance
MANUAL NO. SIEP C710636 04D
Quick Reference Sheet
Copyright © 2014 YASKAWA ELECTRIC CORPORATION. All rights reserved.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of Yaskawa. No patent
liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly
striving to improve its high-quality products, the information contained in this manual is subject to change without notice.
Every precaution has been taken in the preparation of this manual. Yaskawa assumes no responsibility for errors or omissions.
Neither is any liability assumed for damages resulting from the use of the information contained in this publication.
u
Quick Reference
Easily Set Parameters for Specific Applications
Preset parameter defaults are available for setting up applications.
Refer to Application Selection on
page 154.
Run a Motor One Frame Larger
This drive can operate a motor one frame size larger when running variable torque loads such as fans and pumps.
Refer to C6-01: Drive Duty Mode
Selection on page 233.
Drive a Synchronous PM Motor
The drive can operate synchronous PM motors.
Refer to Subchart A-3: Operation with Permanent
Magnet Motors on page 151.
Perform Auto-Tuning
Automatic tuning sets motor parameters.
Refer to Auto-Tuning on page 157.
Maintenance Check Using Drive Monitors
Use drive monitors to check if fans, capacitors, or other components require maintenance.
Refer to Performance Life Monitors Maintenance
Monitors on page 421.
Fault Display and Troubleshooting
Refer to Drive Alarms, Faults, and Errors on page 362
and
Refer to Troubleshooting without Fault Display on page 406.
Standards Compliance
Refer to European Standards on page 650
and
Refer to UL and CSA Standards on page 656.
YASKAWA ELECTRIC
SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
3
This Page Intentionally Blank
4
YASKAWA ELECTRIC
SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
Table of Contents
QUICK REFERENCE ....................................................................................... 3
i. PREFACE & GENERAL SAFETY.................................................................. 17
i.1
Preface ....................................................................................................................... 18
Applicable Documentation....................................................................................................... 18
Symbols................................................................................................................................... 18
Terms and Abbreviations ........................................................................................................ 18
Trademarks ............................................................................................................................. 19
i.2
General Safety ........................................................................................................... 20
Supplemental Safety Information ............................................................................................ 20
Safety Messages..................................................................................................................... 21
General Application Precautions ............................................................................................. 23
Motor Application Precautions................................................................................................. 25
Drive Label Warning Example................................................................................................. 27
Warranty Information............................................................................................................... 28
1. RECEIVING .................................................................................................... 29
1.1 Section Safety............................................................................................................ 30
1.2 General Description .................................................................................................. 31
U1000 Model Selection ........................................................................................................... 31
Control Mode Selection ........................................................................................................... 31
1.3 Model Number and Nameplate Check ..................................................................... 34
Nameplate ............................................................................................................................... 34
Model Number......................................................................................................................... 37
1.4 Drive Models and Enclosure Types ......................................................................... 39
Drive Models 2o0028 to 2o0248 and 4o0011 to 4o0930.................................................... 39
Harmonic Filter Modules ......................................................................................................... 40
1.5 Component Names.................................................................................................... 41
IP00/Open Type Enclosure ..................................................................................................... 41
IP20/UL Type 1 Enclosure ...................................................................................................... 47
Harmonic Filter Modules ......................................................................................................... 52
Front Views ............................................................................................................................. 53
2. MECHANICAL INSTALLATION..................................................................... 55
2.1 Section Safety............................................................................................................ 56
2.2 Mechanical Installation ............................................................................................. 58
Installation Environment .......................................................................................................... 58
YASKAWA ELECTRIC
SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
5
Zgłoś jeśli naruszono regulamin