J1000
The basic inverter
V/f controlled inverter
Good torque performance (150% / 3 Hz)
Double rating ND 120%/1min and HD 150%/1 min
Overload detection function (150% during 60s)
Motor thermal function
Freely configurable V/f curve
5 programmable digital input
1 programmable digital output
1 programmable analog output
Optional RS-232C/485 communication - Modbus,
CE, UL, cUL and TUV, RoHS
Ratings
• 200 V Class single-phase 0.1 to 1.5 kW
• 200 V Class three-phase 0.1 to 4.0 kW
• 400 V Class three-phase 0.2 to 4.0 kW
System configuration
Power
Supply
RS232 Communications cable with PC
MCCB
US
B
Co
py
it
Un
R
ER
M
CO
Re
ad
RJ-45 / USB
Adapter
WA
KA
USB Cable
CX-Drive
CX-One
Ve
rify
Co
py
CK
LO
-1
OP
JV
81
YAS
AC Reactor
Remote Operator
Extansion Cable
Filter
Communication Unit
LED Remote
Operator
J1000
Mounting Accesories
Choke
Braking Resistor
Motor
DC Reactor
Ground
J1000
1
Specifications
Type designation
JZAB0P1BAA
Version
J1000
series
Z:
A:
European
standard
specifications
Standard specs
Coating
specs:
A:
Standard
B:
IP20
Voltage:
B:
Single-phase
200 VAC
2: Three-phase 200 VAC
4: Three-phase 400 VAC
[”P” indicates
a
decimal point]
Max.
applicable
motor output
0P1: 0.1 kW
4P0: 4 kW
~
200 V class
Single-phase: JZA@
Motor
kW
1
B0P1
20P1
0.12
0.18
0.3
0.8
1.2
B0P2
20P2
0.25
0.37
0.6
1.6
1.9
B0P4
20P4
0.4
0.55
1.1
3.0
3.5
B0P7
20P7
1.1
1.1
1.9
5.0
6.0
400 Hz
B1P5
21P5
1.5
2.2
3.0
8.0
9.6
-
22P2
2.2
3.0
4.2
11.0
12.0
-
24P0
4.0
5.5
1
6.7
17.5
21.0
Three-phase: JZA@
For HD setting
For ND setting
Inverter capacity kVA
Rated output current (A) at HD
Rated output current (A) at ND
Max. output voltage
Max. output frequency
Rated input voltage
and frequency
Allowable voltage
fluctuation
Allowable frequency
fluctuation
Output
characteristics
Proportional to input voltage: 0..240 V
Single-phase 200..240 V 50/60 Hz
3-phase 200..240 V 50/60 Hz
-15%..+10%
+5%
Power
supply
1.
Based on a standard 4-pole motor for maximum applicable motor output:
Heavy Duty (HD) mode with a 150% overload capacity
Normal Duty (ND) mode with a 120% overlaod capacity
400 V class
Motor
kW
1
Three-phase: JZA@
For HD setting
For ND setting
Inverter capacity kVA
Rated output current (A) at HD
Rated output current (A) at ND
Max. output voltage
Max. output frequency
Rated input voltage
and frequency
Allowable voltage
fluctuation
Allowable frequency
fluctuation
Output
characteristics
40P2
0.37
0.37
0.9
1.2
1.2
40P4
0.55
0.75
1.4
1.8
2.1
40P7
1.10
1.5
2.6
3.4
4.1
41P5
1.5
2.2
3.7
4.8
5.4
400 Hz
42P2
2.2
3.0
4.2
5.5
6.9
43P0
3.0
4.0
5.5
7.2
8.8
44P0
4.0
5.5
7.2
9.2
11.1
0..480V (proportional to input voltage)
3-phase 380..480 VAC, 50/60 Hz
-15%..+10%
+5%
Power
supply
1.
Based on a standard 4-pole motor for maximum applicable motor output:
Heavy Duty (HD) mode with a 150% overload capacity
Normal Duty (ND) mode with a 120% overlaod capacity
2
Frequency inverters
Specifications
Commom specifications
Model number
JZA@
Control methods
Output frequency range
Frequency tolerance
Control functions
Resolution of frequency set value
Resolution of output frequency
Overload capability
Frequency set value
Braking torque
(short term peak torque)
V/f Characteristics
Inputs signals
Specifications
V/f control
0.1..400 Hz
Digital set value: ±0.01% (-10..+50 ºC)
Analogue set value: ±0.1% (25 ±10 ºC)
Digital set value: 0.01 Hz (<100 Hz), 0.1 Hz (>100 Hz)
Analogue set value: 1/1000 of maximum frequency
0.01 Hz
Heavy duty use: 150% rated output current for one minute
Normal duty use: 120% rated output current for one minute
0..10 V (20 kΩ), 4..20 mA (250
Ω),
0..20 mA (250
Ω)
Frequency setting value (selectable)
Short-term average deceleration torque: 150% (up 1.5 kW), 100% (for 1.5 kW), 50% (for 2.2 kW), 20% (fof bigger size)
Continous regenerative torque: Aprox 20% (125% with optional braking resistor, 10%ED, 10 s, braking transistor built itn)
Possible to program any V/f pattern
Five of the following input signals are selectable: Forward/reverse run (3-wire sequence), fault reset, external fault (NO/NC
contact input), multi-step speed operation, Jog command, accel/decel time select, external baseblock, speed search com-
mand, UP/DOWN command, accel/decel hold command, LOCAL/REMOTE selection, emergency stop fault, emergency
stop alarm, self test
Following output signals are selectable (NO/NC contact output, MA, MB and MC realay: Fault, running, zero speed, speed
agree, frequency detection (output frequency <= or => set value), undervoltage detection, minor error, during baseblock, op-
eration mode, inverter run ready, during fault retry, reverse running, during speed search.
Full-range automatic torque boost, slip compensation, 9-step speed operation (max.), restart after momentary power loss,
DC injection braking current at stop/start (50% of inverter rated current, 0.5 sec, or less), frequency reference bias/gain, ME-
MOBUS communications (Option), fault retry, speed search, frequency upper/lower limit setting, overtorque detection, fre-
quency jump, accel/decel time switch, accel/decel prohibited, S-curve accel/decel
1 analogue input, 0..10 V, 4..20 mA, 0..20 mA
0.01..6000 s
Optionally frequency, current or set value
Error and status LED
Electronic thermal overload relay
Motor coasts to a stop at approx. 250% of inverter rated current
Heavy Duty: Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Normal Duty: Motor coasts to a stop after 1 minute at 120% of inverter rated output current
Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Stops when DC bus voltage is approx. 190 V or less (double for 400 V class)
(approx. 150 V or less for single-phase series)
Following items are selectable: not provided (stop if power loss is 15 ms or longer), continuous operation if power loss is
approx. 0.5 s or shorter, continuous operation
Protected by thermistor
Stall prevention during acceleration/deceleration and constant speed operation
Protected by electronic circuit (operation level is approx. 250% of rated output current)
Indicates until the main circuit voltage reaches 50 V.
IP20, NEMA1
Cooling fan is provided for 200 V (3-phase) 0.75 kW (1HP) to 4.0 KW, 200V (single-phase) 1.5 KW
400 V 1.5 kW (2HP) to 4.0 KW, others are self-cooling
95% RH or less (without condensation)
-20 ºC..+60 ºC (short-term temperature during transportation)
Indoor (no corrosive gas, dust, etc.)
Max. 1000 m
Up to 9.8 m/s at 10 to less than 20 Hz, Up to 6.37 m/s
2
at 20 to 50 Hz
2
Functionality
Protection functions
Ambient conditions
Output signals
Standard functions
Analogue inputs
Braking/acceleration times
Display
Motor overload protection
Instantaneous overcurrent
Overload
Overvoltage
Undervoltage
Momentary power loss
Cooling fin overheat
Stall prevention level
Ground fault
Power charge indication
Degree of protection
Cooling
Ambient humidity
Storage temperature
Installation
Installation height
Vibration
J1000
3
Dimensions
IP 20 type 0.1 to 4 kW
Figure 1
D2
W1
2-M4
t1
Figure 2
W1
4-M4
D2
H1
H
H2
H1
H
W
D
W
H2
D1
t1
D1
D
Voltage class
Max. applicable
motor output kW
0.12
0.25
Inverter model JZA@
B0P1
B0P2
B0P4
B0P7
B1P5
20P1
20P2
20P4
20P7
21P5
22P2
24P0
40P2
40P4
40P7
41P5
42P2
43P0
44P0
Figure
Dimensions in mm
W1
56
118
H1
W
68
128
108
H
D
76
118
137.5
154
76
3
5
t1
3
5
H2
D1
6.5
38.5
58
6.5
38.5
58
65
10
28
5
154
128
140
143
5
D2
67.5
109.5
129
145.5
67.5
99.5
119.5
120.5
129
134.5
72.5
90.5
129
58
145.5
134.5
Weight
0.6
0.6
1.0
1.7
1.8
0.6
0.6
0.9
1.1
1.7
1.7
2.4
1.0
1.2
1.7
1.7
1.7
1.7
65
2.4
1
Single-phase
200 V
0.55
1.1
1.5
0.12
0.25
0.55
2
96
1
56
118
68
128
108
140
108
128
129
137.5
143
81
99
137.5
128
5
5
Three-phase 200
V
1.1
1.5
2.2
4.0
0.37
0.55
1.1
2
96
128
Three-phase
400 V
1.5
2.2
3.0
4.0
2
96
118
108
Schaffner footprint Filters
Schaffner model
A1000-FIV2010-SE
3x200 V
A1000-FIV2020-SE
A1000-FIV2030-SE
1x200 V
A1000-FIV1010-SE
A1000-FIV1020-SE
A1000-FIV3005-SE
3x400 V
A1000-FIV3010-SE
A1000-FIV3020-SE
Dimensions
A
194
169
174
169
169
169
169
174
B
82
111
144
71
111
111
111
144
C
50
50
50
45
50
45
45
50
D
160
135
135
135
135
135
135
135
E
181
156
161
156
156
156
156
161
F
62
91
120
51
91
91
91
120
G
5.3
5.5
5.3
5.3
5.3
5.3
5.3
5
H
M5
M5
M5
M5
M5
M5
M5
M5
I
25
25
25
22
25
22
22
25
J
56
96
128
56
96
96
96
128
K
118
118
118
118
118
118
118
118
L
M4
M4
M4
M4
M4
M4
M4
M4
Weight
KG
0.40
0.58
0.90
0.44
0.75
0.5
0.7
0.9
4
Frequency inverters
Rasmi footprint Filters
Rasmi model
A1000-FIV2010-RE
3x200 V
A1000-FIV2020-RE
A1000-FIV2030-RE
1x200 V
A1000-FIV1010-RE
A1000-FIV1020-RE
A1000-FIV3005-RE
3x400 V
A1000-FIV3010-RE
A1000-FIV3020-RE
Dimensions
W
82
111
144
71
111
111
111
144
H
50
50
50
45
50
45
45
50
L
194
194
174
169
169
169
169
174
X
181
181
161
156
156
156
156
161
Y
62
62
120
51
91
91
91
120
M
M4
M4
M4
M4
M4
M4
M4
M4
Weight
KG
0.8
1.1
1.3
0.6
1.0
1.1
1.1
1.3
Chokes
Description
A1000-FEV2102-RE
A1000-FEV2515-RE
D
diameter
21
25
Motor
KW
< 2.2
< 15
L
85
105
W
22
25
Dimensions
H
X
46
70
62
90
Y
-
-
m
5
5
Weight
Kg
0.1
0.2
W Y
X
Ø
m
L
H
Ø
d
Resistor Dimensions
A1000-REJ0K15xxx
A1000-REJ0K10xxx
168
11.5
182
27
105
45
20
36
J1000
5