TECHNICAL NOTE FOR ALCATEL REPAIR CENTERS
Only for BE5
Information about :
1: Track Point failure on BE5 C
If the user complains about track point problems and if the
hardware technical level of the handset is lower than
3.2
, you
must change the front casing.
2: LiPo and Ni Mh batteries
If you receive a handset with its battery , you must check
the battery reference .
In case its reference is : 3DS0xxxxAAAA , you must
exchange it by a 3DS0xxxxABAA . Every 3DS0xxxxAAAA
battery which is changed , must be stored in a non conformity
area .