Siemens -- SX 1.pdf

(366 KB) Pobierz
Information and Communication Mobile
Mobile Phones
SX1
Level 2.5
Repair Documentation
V 1.0
V 1.0
SX1
Page
1
of
40
Company Confidential
Copyright 2003© Siemens AG
ICM MP CCQ GRM
06/03
Information and Communication Mobile
Mobile Phones
Table of Content
1
2
3
4
5
6
7
8
9
Introduction ......................................................................................................................... 3
I/O Connector (Slim Lumberg) ........................................................................................... 4
Battery Connector................................................................................................................ 8
Speaker Connector............................................................................................................. 11
Antenna Connector ............................................................................................................ 14
Card Reader ....................................................................................................................... 17
MMI Connector ................................................................................................................. 20
IRDA ................................................................................................................................. 23
Camera Connector ............................................................................................................. 26
10 Joystick Switch .................................................................................................................. 29
11 Keyboard LEDs ................................................................................................................. 32
12 MMI Connector ................................................................................................................. 32
13 Display Connector ............................................................................................................. 38
V 1.0
SX1
Page
2
of
40
Company Confidential
Copyright 2003© Siemens AG
ICM MP CCQ GRM
06/03
Information and Communication Mobile
Mobile Phones
1 Introduction
SX1 product family, consists of 1 tripleband (GSM900, GSM1800 and GSM1900) handset
Partnumber on IMEI label:
SX1:
S36880-S6500-#xxx
, while # may be any letter (A-Z) and xxx may be any number from 100, 101, 102....
This manual is intended to help you carry out repairs on level 2.5, meaning limited
component repairs. The documented failure highlights should be repaired in the local
workshops.
All repairs have to be carried out in an environment set up according to the ESD (Electrostatic
Discharge Sensitive Devices) regulations defined in international standards.
If you have any questions regarding the repair procedures or technical questions about the
spare parts do not hesitate to contact our technical support team in Kamp-Lintfort, Germany:
Tel.: +49 2842 95 4666
Fax: +49 2842 95 4302
E-mail: st-support@klf.siemens.de
V 1.0
SX1
Page
3
of
40
Company Confidential
Copyright 2003© Siemens AG
ICM MP CCQ GRM
06/03
Information and Communication Mobile
Mobile Phones
2 I/O Connector (Slim Lumberg)
2.1.
2.1.1.
2.1.2.
2.1.3.
Affected Units
Type:
Affected IMEIs / Date Codes:
Affected SW Versions:
SX1
All / All
All
2.2.
2.2.1.
Fault Description
Fault Symptoms for customers:
- Charging problems.
- Problems with external loudspeaker or microphone when using a car kit.
- Problems with accessories connected at the I/O - connector.
- Problems with SW booting
2.2.2.
Fault Symptoms on GSM Tester:
This fault cannot be detected with a GSM-Tester
2.3.
Priority:
Mandatory
Repair
Optional
Not Yet Defined
V 1.0
SX1
Page
4
of
40
Company Confidential
Copyright 2003© Siemens AG
ICM MP CCQ GRM
06/03
Information and Communication Mobile
Mobile Phones
2.4.
2.4.1.
Repair Documentation:
Description of procedure:
2.4.1.1. Diagnosis:
Visually check the bottom connector. Watch for oxidation and dry solder joints.
2.4.1.2. Repair by component change:
Use hot air blower remove defective I/O connector.
Avoid excessive heat!
Watch surrounding components!
Resolder new I/O connector afterwards.
2.4.1.3. Repair by Software booting:
Not possible!
2.4.1.4. Test:
Retest handset after repair.
2.4.2.
List of needed material:
2.4.2.1. Components:
I/O Connector SX1
Placement: X2500
Part-Number: L36334-Z93-C303
2.4.2.2. Jigs and Tools:
Hot Air Blower
Soldering Iron
V 1.0
SX1
Page
5
of
40
Company Confidential
Copyright 2003© Siemens AG
ICM MP CCQ GRM
06/03